| Senotec SLCA-4/20 amplifier, part no. 70 420 00 | - Housing material
- aluminum
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 20 mA, ensuring minimal power consumption
- Connections
- M12x1, 4-pin
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Analog output
- 4-20 mA, with the ability to monitor different levels via LED indicator
- Operating temperature range
- -10... 60°C, allows operation in various climatic conditions
| PLN 1,608.13 net PLN 1,978.00 gross | In stock |
|---|
| Senotec SLCA-2 PNP-NO Amplifier Cat. No. 70 002 00 | - Output function
- 2x PNP – normally open, 2x 100 mA
- Housing material
- aluminum
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 20 mA, ensuring minimal power consumption
- Connections
- M12x1, 4-pin
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Operating temperature range
- -10... 60°C, allows operation in various climatic conditions
| PLN 1,559.35 net PLN 1,918.00 gross | In stock |
|---|
| Senotec SLCA-1 PNP-NO Amplifier Cat. No. 70 001 00 | - Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 20 mA, ensuring minimal power consumption
- Connections
- M12x1, 4-pin
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Analog output
- 4-20 mA, with the ability to monitor different levels via LED indicator
- Operating temperature range
- -10... 60°C, allows operation in various climatic conditions
| PLN 1,486.99 net PLN 1,829.00 gross | In stock |
|---|
| Senotec SLCPF-4/20 analog amplifier, part no. 60 420 00 | - Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 20 mA, ensuring minimal power consumption
- Connections
- M12x1, 4-pin
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Analog output
- 4-20 mA, with the ability to monitor different levels via LED indicator
- Operating temperature range
- -10... 60°C, allows operation in various climatic conditions
| PLN 1,489.43 net PLN 1,832.00 gross | In stock |
|---|
| Senotec SLCPF-DUO PNP-NO amplifier, part no. 60 202 00 | - Output function
- 2 x PNP – normally open, 2 x 100 mA
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 20 mA, ensuring minimal power consumption
- Connections
- M12x1, 4-pin
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Operating temperature range
- -10... 60°C, allows operation in various climatic conditions
| PLN 1,901.63 net PLN 2,339.00 gross | In stock |
|---|
| Senotec SLCPF-1 PNP-NO Amplifier Cat. No. 60 001 00 | - Output function
- PNP, normally open, 100 mA
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 20 mA, ensuring minimal power consumption
- Connections
- M12x1, 4-pin
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Operating temperature range
- -10... 60°C, allows operation in various climatic conditions
| PLN 1,343.09 net PLN 1,652.00 gross | In stock |
|---|
| Senotec CLS 33-L20M0 amplifier, part no. 30 033 20M | - Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 2 m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- -25... 60°C, allows operation in various climatic conditions
| PLN 1,252.85 net PLN 1,541.00 gross | In stock |
|---|
| Senotec CLS 33-L05M0 amplifier, part no. 30 033 05M | - Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 0.5 m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- -25... 60°C, allows operation in various climatic conditions
| PLN 1,200.81 net PLN 1,477.00 gross | In stock |
|---|
| Senotec CLS 33-L05 amplifier, part no. 30 033 05 | - For use with probes
- R, S, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 0.5m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 10... 60°C, allows operation in various climatic conditions
| PLN 1,239.02 net PLN 1,524.00 gross | In stock |
|---|
| Senotec CLS 33-L20 amplifier, part no. 30 033 20 | - For use with probes
- R, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 2.7m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,252.85 net PLN 1,541.00 gross | In stock |
|---|
| Senotec CLS 33-L27M0 amplifier, part no. 30 033 27M | - For use with probes
- R, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 2.7m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,265.85 net PLN 1,557.00 gross | In stock |
|---|
| Senotec CLS 33-E5-L20 amplifier, part no. 30 033 225 | - For use with probes
- R, S, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 2m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 10... 60°C, allows operation in various climatic conditions
| PLN 1,299.19 net PLN 1,598.00 gross | In stock |
|---|
| Senotec CLS 45-AV-M12 amplifier part no. 30 045 00 | - For use with probes
- R, S, C Series
- Output function
- antivalent, 2 x 0…250 mA
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection
- M12x1, 4-pinowe
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,339.84 net PLN 1,648.00 gross | In stock |
|---|
| Senotec CLS 45-L05 amplifier, part no. 30 045 05 | - For use with probes
- R, S, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 0.5m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,313.01 net PLN 1,615.00 gross | In stock |
|---|
| Senotec CLS 45-L50 amplifier, part no. 30 045 50 | - For use with probes
- R, S, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 5.0m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,366.67 net PLN 1,681.00 gross | In stock |
|---|
| Senotec CLS 45-L60 amplifier, part no. 30 045 60 | - For use with probes
- R, S, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 6.0m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,366.67 net PLN 1,681.00 gross | In stock |
|---|
| Senotec CLS 45-L80 amplifier, part no. 30 045 80 | - For use with probes
- R, S, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 8.0m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,373.98 net PLN 1,690.00 gross | In stock |
|---|
| Senotec CLS 45-L100 amplifier, part number 30 045 100 | - For use with probes
- R, S, C, W Series
- Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- 4x0.25mm², length 10m
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 25... 60°C, allows operation in various climatic conditions
| PLN 1,386.99 net PLN 1,706.00 gross | In stock |
|---|
| Senotec CLS 45-NO amplifier, part no. 30 045 NO | - For use with probes
- R, S, C Series
- Output function
- 1 x PNP - NO
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection
- M12x1, 4-pinowe
- Degree of protection
- IP 40, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 10... 60°C, allows operation in various climatic conditions
| PLN 1,339.84 net PLN 1,648.00 gross | In stock |
|---|
| Senotec CLS 80-L05 amplifier, part no. 30 080 05 | - For use with probes
- R, C Series
- Output function
- 2 x PNP - NO
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- LIYCY 4x0.25, length 0.5m
- Degree of protection
- IP 53, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 10... 60°C, allows operation in various climatic conditions
| PLN 1,979.67 net PLN 2,435.00 gross | In stock |
|---|
| Senotec CLS 80-L60 amplifier, part no. 30 080 60 | - For use with a probe
- R3E-8/16L12
- Output function
- 2 x PNP - NO
- Housing material
- ABS, resistant to damage
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- Typically 50 mA
- Connection cable
- LIYCY 4x0.25, length 6m
- Degree of protection
- IP 53, in accordance with the IEC60529 standard, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Operating temperature range
- 10... 60°C, allows operation in various climatic conditions
| PLN 2,047.15 net PLN 2,518.00 gross | In stock |
|---|
| Senotec CSV 55 amplifier part no. 10 055 00 | - Output function
- NO relay contact, normally open, 2A / 250V
- Housing material
- ABS / transparent plastic cover
- Protection circuit
- Built-in, ensuring reliable operation
- Connection cable
- 4x075mm², length 1.5m
- Degree of protection
- IP 40, in accordance with EN 60529, provides protection against dust
- Voltage range
- 110 … 240 V /AC
- Temperature range
- working temperature: -10... 50°C, allows operation in various climatic conditions
| PLN 1,811.38 net PLN 2,228.00 gross | In stock |
|---|
| Senotec CLC 40-SM8 amplifier, part no. 20 040 08 | - Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- G AL SI 12 / transparent plastic cover
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- 50mA
- Connection
- 3-stykowemale socket, Binder 768 series, locking screw M18x1
- Degree of protection
- IP 40, in accordance with EN 60529, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Temperature range
- working temperature: -10... 60°C, allows operation in various climatic conditions
| PLN 1,380.49 net PLN 1,698.00 gross | In stock |
|---|
| Senotec CLC 28-IMA amplifier, part no. 20 028 99 | - Output function
- NO relay contact, normally open, 1A / 150V
- Housing material
- G AL SI 12 / transparent plastic cover
- Protection circuit
- Built-in, ensuring reliable operation
- No-load current
- 50mA
- Connection cable
- 4x025mm², length 5m
- Degree of protection
- IP 40, in accordance with EN 60529, provides protection against dust
- Voltage range
- 18 … 30 V /DC
- Temperature range
- working temperature: -10... 60°C, allows operation in various climatic conditions
| PLN 1,404.07 net PLN 1,727.00 gross | In stock |
|---|